磁珠分选

点击图片查看原图
单价: 4794.00
品牌: Biotool
销量: 累计出售 0
评价: 已有 0 条评价
人气: 已有 51 人关注
更新: 2021-04-03
数量: 减少 增加份 库存999份
立即购买   加入购物车
看了又看 更多>
 
 
货号: B23704
保存条件: 零下20摄氏度低温保存
供应商: Biotool
数量: 大量现货
英文名: GSH Magnetic Beads for Protein Purification
规格: 50 mL (10 mL X5)

磁珠分选

Description

GSH Magnetic Beads are made of a novel functional material specially designed for the efficient and fast purification of Glutathione S-transferase (GST)-fusion proteins. These beads enable one-step purification of proteins of interest directly from the biological samples via magnetic separation, which greatly simplify the purification techniques and optimize the purification efficiency. Therefore, we recommend the use of Biotool’s GSH Magnetic Beads for the easy purification of GST-fusion proteins in scientific research and industrial areas.

Protocols

The binding capability of the target proteins and the beads has a direct effect on the purification efficiency, as does the preparation of the buffer on the recovery ratio and the purity of the target proteins. Therefore, users should design a preliminary experiment before a large-scale purification to select the appropriate buffer, which is recommended to include binding buffer (Buffer A) and elution buffer (Buffer B). A sample protocol depicting a GST fusion- protein purification procedure with a relatively strong binding capability is provided below.

1. Preparation of Buffer
Buffer A (Binding Buffer): 140 mM NaCl, 2.7 mM KCl, 10 mM Na2HPO4, 1.8 mM KH2PO4, pH 7.4
Buffer B (Elution Buffer): 50 mM Tris- HCl, 10 mM GSH, pH 8.0. Preparation Method: Add 0.307g GSH to 100 mL 0.1M Tris- HCl, then adjust pH to 8.0 with 0.1 M HCl and add deionized water to a total volume of 100 mL.
Note:
1. GSH is oxidized quickly, so prepare Buffer B immediately before use.
2. The binding capability between various GST- fusion proteins and the beads is different. Most GST- fusion proteins can be eluted by Buffer B which contains 10 mM GSH. A few GST- fusion proteins which have a relatively strong binding capability, may require prolonged elution, increased time of the elution, or increasedconcentration of GSH in Buffer B.
3. To increase the stability of the target proteins, users may add 1~5 mM EDTA, 1~10 mM DTT, 0.1~ 1% Triton X- 100, or 0.1~ 1% Tween 20 to Buffer A and Buffer B.

2. Preparation of Samples
This User Manual provides preparation of three samples as follows:
A. Intracellular- expressed proteins in bacteria, yeasts and other cells: dilute the cells with Buffer A and add a protease inhibitor (e.g. 1mM PMSF); lyse cells in an ultrasonic ice bath to generate the crude protein samples. Once the samples are homogenized, add nucleases to the crude samples and place on ice for 30 min to degrade nucleic acids. If the yield of the target proteins is expected to be low, centrifuge the crude proteins to concentrate sample.
B. Extracellular- expressed proteins: harvest the supernatant containing the extracellular- expressed proteins and add equal amounts of Buffer A to generate the crude protein samples.
C. Intracellular- expressed proteins in animal cells: wash animal cells once with PBS, scrape into a tube and centrifuge. Discard the supernatant and resuspend the cells with Buffer A containing 1% (v/v) Triton X- 100 or 1% (v/v) NP- 40; add a protease inhibitor (e.g. 1mM PMSF); lastly, place the tube on ice for 10 min to generate the crude protein samples.

3. Pretreatment of Beads
The amount of beads used is determined by users’ calculations according to the target protein yield and the beads’ capacity. For example, for a protein expressed in E.coli, 1g-wet weight of microbes can be obtained from 250 mL broth. The yield of the target protein will come to 5~10 mg by the experimental estimation, and users will need 10 mL 10% beads suspension for that target protein purification. Details of this example are presented as follows.
(1) Homogenize the Biotool GSH Magnetic Beads fully with a vortex, and pipette 10mL beads suspension to a centrifuge tube;
(2) Place the tube on the magnetic separator, discard the supernatant when the liquor becomes clear;
(3) Add 5~10 mL Buffer A to the tube, close the tube cap tightly, oscillate the tube on a vortex for 15s to resuspend the beads; place the tube on the separator for a magnetic separation* and discard the supernatant; 
(4) Repeat step (3) twice.
Attention *: in order to decrease the loss of beads during magnetic separation, close the centrifuge tube cap tightly and keep the tube on the separator until the liquid becomes clarified. Next, invert the separator and the tube for several times by hand to wash the beads adherent to the cap by the clear liquid; let the tube stand on the bench top until the liquid settles and becomes clear again.

4. Binding of Target Protein and Beads
(1) Suspend 1g- wet weight of microbes with 10 mL Buffer A, to lyse the cells. This is the crude protein samples;
(2) Apply the samples to the tube containing the pretreated beads and close the tube cap tightly;
(3) Vortex the tube for 15 s, then mix/lightly agitate it at room temperature for 20~30 min (if necessary, mix the tube at 4~ 8℃ for 1 h to prevent the target protein degradation);
(4) Place the tube on the magnetic separator for separation, then pipette the supernatant to another centrifuge tube. Take the tube off the magnetic separator and proceed to washing steps.

5. Washing of Beads
(1) Add 5~10 mL Buffer A to the centrifuge tube containing the beads, shake them for 2 min, perform a magnetic separation and pipette the eluate to another tube (keep eluate for a following test);
(2) Add 5~10 mL Buffer A to the centrifuge tube containing the beads to suspend them, pipette the beads suspension to a anew tube to avoid nonspecific-adherent proteins in the previous tube contaminating the target ones; perform a magnetic separation and pipette the supernatant to the eluate tube.

6. Elution of Target Proteins
(1) Add 2~5 mL Buffer B to the tube containing the beads (users may change the elution volume to adjust the concentration of the target proteins if necessary), close the tube cap tightly and mix/shake them at room temperature for 2 min; perform a magnetic separation and collect the eluate into another tube. This is the purified target protein samples;
(2) If necessary, repeat the elution step (1) above once and collect the samples into another tube to examine whether the target proteins have been eluted thoroughly.

7. Washing and Storage of Beads
The beads can be used for purification again after washing treatment. Additionally, for a longtime storage; users may choose different washing methods according to the usage situation of the beads;
Situation 1: When the beads are not repeatedly used for many times, or the binding capability of the beads doesn’t decrease obviously, users may wash the beads by an alternative mode with high pH and low pH.
(1) Add 10 mL Buffer C (0.1 M Tris- HCl, 0.5 M NaCl, pH 8.5) to the used beads, place the tube on a vortex for 60 s, perform a magnetic separation and discard the supernatant;
(2) Add 10 mL Buffer D (0.1 M Sodium Acetate, 0.5 M NaCl, pH 4.5), place the tube on a vortex for 60 s, perform a magnetic separation and discard the supernatant;
(3) Repeat step (1) and (2) above twice.
Situation 2: When the beads are repeatedly used for many times, the binding capability of the beads and the target proteins will decrease, due to the precipitation, denaturation or accumulation of the nonspecific adherent proteins. Users may adopt the following methods to wash the precipitates or denatured proteins from the beads:
(1) Wash the beads with 5mL 6 M Guanidine Hydrochloride twice, place the tube on a vortex for 60 s each time, perform a magnetic separation and discard the supernatant;
(2) Wash the beads with 10 mL 1×PBS for three times, place the tube on a vortex for 60s each time, perform a magnetic separation and discard the supernatant.
In order to remove the hydrophobic- conjugated substances, wash the beads as follows:
(1) Wash the beads with 5 mL 70% Ethanol or 0.1% non-ionic surfactant for three times, place the tube on a vortex for 60 s each time, perform a magnetic separation and discard the supernatant;
(2) Wash the beads with 10 mL 1×PBS for three times, place the tube on a vortex for 60 s each time, perform a magnetic separation and discard the supernatant.
After finishing the washing operations for Situation 1 and 2, if users need to use the beads again for protein purification, wash the beads with Buffer A for 2~3 times as in the protein purification steps. If storing them for a brief time, wash the beads with 20% Ethanol for 2~3 times, then add 20% (v/v) Ethanol to the beads to a total volume of 10 mL and store them at 4~8℃.

Optimization of Protein Purification

The operation protocols above are appropriate for purifying most GST-fusion proteins. To increase the recovery ratio and purity of the target proteins, users may optimize the purification procedures in the following ways, according to the different binding property of the target proteins and the beads.

Reference for Increasing the Recovery Ratio of Target Proteins

(1) Prolong the incubation of the proteins and the beads;
(2) Add 1~10 mM DTT to the samples and buffer, which helps increase the binding capability of certain GST- fusion proteins and the beads;
(3) Add various protease inhibitors to prevent the protein degradation;
(4) Increase the amount of beads;
(5) Prolong the elution of the proteins or increase times of the elution;
(6) Use the just- prepared fresh Buffer B to ensure efficient elution of the target proteins.

Reference for Increasing the Purity of Target Proteins

(1) Avoid ultrasonic lysis to keepthe GST tag and the target protein intact;
(2) Add various protease inhibitors to prevent the protein degradation;
(3) Add 0.1% Tween 20 or 2% NP- 40 to the samples and buffer to decrease the adsorption of the nonspecific proteins;
(4) Prolong the washing of the proteins and increase times of the washing;
(5) Elute the target proteins by GSH gradient concentration.

Attention:

1. Read the User Manual carefully before the first use;
2. Avoid freezing, drying and high-speed centrifugation when using and storing the beads;
3. Shake the beads thoroughly to keep them a homogeneous suspension before use;
4. Choose well-qualified pipette tips and centrifuge tubes in case of the beads loss from adherence or leakage when mixing;
5. When mixing the beads and the solutions, aspirate the beads with the pipette repeatedly or vortex briefly, if the solution is too thick to resuspend manually;
6. To analyze the purification process and optimize the protein purification procedure, keep the removed supernatant (eluate) assay for protein detection if necessary;
7. The product can be used multiple times, as long as the same kinds of proteins are being assayed; when purifying a different kind of protein sample, choose the new beads to prevent the interactive contamination;
8. The product should be used with the magnetic separator;
9. The product can be stabily stored at 4℃~8℃ for two years;
10. The product can only be used for research purposes.


更多详情请访问唯一官方网站http://www.biotool.com/product/gsh-magnetic-beads-for-protein-purification.html
温馨提示:不可用于临床治疗。